顱內血栓抽吸系統 Intracranial Thrombus Aspiration System

▸0.088" Ultra-Large Inner Diameter
▸Includes Guiding catheter
▸ Thrombectomy Aspiration pump - efficient aspiration
製造商:Lifetech NeuroNova
  •  

    [Aspiration Catheter] : Stable Procedural Control
    Effective length: 1200|1150|1050|950

    Spring coil + Braided double-layer structure design

    • Enhances anti-kinking performance, quickly navigates tortuous vessels to reach the lesion site.
    • Resists bending and collapsing, ensuring smooth flow path and stable control, efficient aspiration. 

    Introduced via vertebral or femoral artery

    • Provides enhanced support via femoral artery with a guiding catheter.
    • 6F catheter can be navigated through tortuous arteries using a guidewire or guiding catheter.

    10-Segment Tapered Design

    • Significantly enhances pushability and positional accuracy.
    • 0.088" catheter reaches M1; 0.071" catheter reaches M1–M2. 

    Ultra-smooth hydrophilic coating

    • Excellent pushability with low resistance.
    • Smooth navigation through tortuous vessels and Rapid and Accurate Positioning.
  •  

    [Large Lumen Design] : Powerful Aspiration

    Specification: 0.088 "(2.24 mm) 8Fr

    Specification: 0.071 "(1.80 mm) 6Fr

    Available Sizes: 0.088" (2.24 mm) | 0.071" (1.80 mm)

    • Distal tip cross-sectional area of the 0.088" catheter is up to 50% larger than conventional 0.071" catheters.
    • Delivers significantly higher aspiration efficiency.
    • Minimizes thrombus displacement or detachment and helps shorten procedure time.
  •  

    [Includes Guiding catheter] : First Fully Integrated Configuration

    Enhanced Pushability

    • 5-segment progressive taper provides optimized pushability.

    Reduce risk of vascular injury 

    • Custom size-matching interface.
    • Effectively prevents step-off at vessel bifurcations.
    • Ensures smoother overall system transit.

    Outstanding Visibility

    • Fully radiopaque design for precise visualization.
    • Clear catheter positioning throughout the procedure for enhanced safety and confidence.

    High-Efficiency Positioning

    • 137 cm working length ensures rapid access to the target anatomy.
    • Extended, super-soft tip enhances pushability and maneuverability.
  •  

    [Thrombectomy Aspiration pump]: Efficient Aspiration
    Safe & Sterile,Designed for Convenience

    • Single-use, sterile aspiration pump to eliminate cross-contamination risks and enhance patient safety.
    • Can be placed directly on the operating table for close-range observation of the aspiration process.
    • No repeated cleaning or re-sterilization required, greatly reduces maintenance effort and cost.

    Compact Size, Powerful Aspiration

    • Delivers stable high negative pressure (>90 kPa) for effective removal of clot.
    • Includes a vacuum syringe to enhance suction force and reduce risk of catheter blockage.
    • Low-flow design helps minimize blood loss during aspiration, providing a safer aspiration experience.

    Easy Control, Real-Time Feedback

    • Single-operator control with one-button for convenient operation.
    • No external power supply required; supports extended operation (>60 minutes of continuous aspiration).
    • Integrated thrombus filter enables rapid clot separation and provides real-time feedback.