Products產品介紹
-
[Aspiration Catheter] : Stable Procedural Control
Effective length: 1200|1150|1050|950Spring coil + Braided double-layer structure design
- Enhances anti-kinking performance, quickly navigates tortuous vessels to reach the lesion site.
- Resists bending and collapsing, ensuring smooth flow path and stable control, efficient aspiration.
Introduced via vertebral or femoral artery
- Provides enhanced support via femoral artery with a guiding catheter.
- 6F catheter can be navigated through tortuous arteries using a guidewire or guiding catheter.
10-Segment Tapered Design
- Significantly enhances pushability and positional accuracy.
- 0.088" catheter reaches M1; 0.071" catheter reaches M1–M2.
Ultra-smooth hydrophilic coating
- Excellent pushability with low resistance.
- Smooth navigation through tortuous vessels and Rapid and Accurate Positioning.
-
[Large Lumen Design] : Powerful Aspiration
Specification: 0.088 "(2.24 mm) 8Fr
Specification: 0.071 "(1.80 mm) 6Fr
Available Sizes: 0.088" (2.24 mm) | 0.071" (1.80 mm)
- Distal tip cross-sectional area of the 0.088" catheter is up to 50% larger than conventional 0.071" catheters.
- Delivers significantly higher aspiration efficiency.
- Minimizes thrombus displacement or detachment and helps shorten procedure time.
-
[Includes Guiding catheter] : First Fully Integrated Configuration
Enhanced Pushability
- 5-segment progressive taper provides optimized pushability.
Reduce risk of vascular injury
- Custom size-matching interface.
- Effectively prevents step-off at vessel bifurcations.
- Ensures smoother overall system transit.
Outstanding Visibility
- Fully radiopaque design for precise visualization.
- Clear catheter positioning throughout the procedure for enhanced safety and confidence.
High-Efficiency Positioning
- 137 cm working length ensures rapid access to the target anatomy.
- Extended, super-soft tip enhances pushability and maneuverability.
-
[Thrombectomy Aspiration pump]: Efficient Aspiration
Safe & Sterile,Designed for Convenience- Single-use, sterile aspiration pump to eliminate cross-contamination risks and enhance patient safety.
- Can be placed directly on the operating table for close-range observation of the aspiration process.
- No repeated cleaning or re-sterilization required, greatly reduces maintenance effort and cost.
Compact Size, Powerful Aspiration
- Delivers stable high negative pressure (>90 kPa) for effective removal of clot.
- Includes a vacuum syringe to enhance suction force and reduce risk of catheter blockage.
- Low-flow design helps minimize blood loss during aspiration, providing a safer aspiration experience.
Easy Control, Real-Time Feedback
- Single-operator control with one-button for convenient operation.
- No external power supply required; supports extended operation (>60 minutes of continuous aspiration).
- Integrated thrombus filter enables rapid clot separation and provides real-time feedback.